Yucel, Gönenç with Cornelia van Daalen, "A Simulation-based Analysis of Transition Pathways for the Dutch Electricity System", 2011 July 24-2011 July 28

Online content

Fullscreen
A Simulation-based Analysis of Transition Pathways for the
Dutch Electricity System

Goneng Yiicel Els van Daalen
G.Yucel@tudelft.nl C.vanDaalen @tudelft.nl

Delft University of Technology
Jaffalaan 5, 2628BX, Delft, the Netherlands

Abstract

Recent developments constitute a backdrop of change for the Dutch electricity
system. Institutional change driven by liberalization, changing economical
competitiveness of the dominant fuels, new technologies, and changing end-user
preferences regarding electricity supply are some examples of these developments. In
order to analyze the conjoint impact of such developments on the internal dynamics of
the electricity system (grid-based and distributed generation), a simulation model is
developed. The simulation experiments with the model indicate the continuation of
fossil fuel dominance as the energy source, and a shift from natural gas to coal seems
likely in the base case. In other cases, it is seen that a transition away from carbon-
intensive mode requires significant regulatory intervention, since technological
developments and ‘greening’ end-users fail to trigger a system-wide transition.
Moreover, it is observed that policies for carbon abatement and renewable generation
support are intertwined, and may lead to unintended shifts of abatement costs to end-
users.

1. Introduction

Large-scale socio-technical systems, such as electricity supply, are characteristically
hard to change. This is primarily due to the past commitments made (social, physical
and economical), intrinsic delays, and strong balancing feedbacks in these systems.
The Dutch electricity system is a typical example of such hard-to-change systems.
However, when the current developments are analyzed, it is seen that there is a
transition-favoring climate for this system.

First of all, the Dutch system has been going through a significant institutional
transformation from a vertically integrated design to a liberalized electricity system in
accordance with the European Union electricity directives since 1998 (van Damme
2005). Briefly, the whole change process resembles a gradual shift from a system
operated by a central operator managing the system for cost minimization, to a system
of independent actors operating their infrastructure for individual profit maximization.
This shift will influence the way the infrastructure will evolve over time (de Vries
2004). However, due to long delays typical to large-scale socio-technical systems, the
impacts of this transformation on the infrastructure’s evolution will be more apparent
in the following years.

The second development is about capacity investment cycles. A detailed survey of the
generator park reveals the fact that an important portion (around 20%) of
conventional plants commissioned during 1970’s (Rédel 2008). These plants are
already beyond their estimated lifetimes, and are expected to be decommissioned
during the following decade. If smaller-scale cogeneration plants and coal-based
generators close to the end of their lifetimes are also considered, the portion of the
generation park to be decommissioned becomes even larger. If this capacity loss is to
be compensated by new capacity, an important change in the generation portfolio may
be possible, also considering the aforementioned management mentality shift. On the
other hand, if the loss is not compensated, the Dutch demand-supply capacity
situation may experience its tightest levels.

Technological developments are also important. These include both developments on
the already utilized technologies, as well as novel ones at the brink of
commercialization. Notable developments are being achieved, and further expected,
in the efficiency and emission performance of coal-based and gas-based combustion
technologies (Lako 2004; Rédel 2008). Besides this, there are new technologies and
practices recently introduced or about to be introduced. These include carbon capture
and storage (CCS) (Smekens 2005; van den Broek, Faaij et al. 2008), fuel cells
(Martinus, Blesi et al. 2005), novel biomass gasification and combustion technologies
(Caputo, Palumbo et al. 2005), off-shore wind-farms, and micro co-generators (m-
CHP) (Pehnt, Cames et al. 2006; Faber, Valente et al. 2008), which may yield
important changes in the way electricity supply system is organized and operated.

Changes in the energy markets, especially in the primary fuel markets, are also
influential in the evolution of the Dutch electricity system. Natural gas-based
generators currently dominate the Dutch system both in terms of generation and
active capacity. Due to the price changes during the last 15 years, natural gas lost its
economic attractiveness significantly (Figure 1). The shift in the generation is already
visible since coal-based generators are getting a bigger share of the base load, while
the share of gas-based generation is shrinking. In the long run, this price-related
development may also lead to a significant shift in the generation portfolio keeping in
mind the upcoming capacity renewal need mentioned above.

Fuel Prices

Euro/Gd

a a a a ee OY

Figure 1. Fuel Prices (Source: CBS Statline (2009))

A change in the social sphere has also been visible in the past decade. At the state
level, dedication for a more environmentally friendly, sustainable and secure system
is apparent. The reflection of this dedication can be seen in the targets set by the
government (e.g. 20% renewable electricity by 2020, Kyoto targets, 6 GW off-shore
wind energy capacity). A change along similar lines is also taking place at the end-
user level: environmental concerns are on the rise against the economic criteria that
can be claimed to dominate end-user behavior in this context up until now. For
industrial and commercial users, it’s the increasing value of environmental
friendliness in the market value of the firm that yields ‘green’ options to be brought
on to the table. In short, an increase in the environmental values, whatever underlying

aI90
driver may be, is apparent. The impact if such a change may be expected to have an
influence on the evolution of the electricity system.

It can be seen that the Dutch electricity system is going through an era during which
significant changes in multiple dimensions, such as_ technological, social,
infrastructural, regulatory and economic, are taking place. The co-existence of these
developments is what makes the current era a climate in which a transition may
emerge. However, whether the system will shift to a newly emerging trajectory, or not
is not apparent. The development trajectory will be shaped by the internal dynamics
of the system under the influence of the aforementioned contextual developments.
This dynamic puzzle constitutes the main motivation behind this study, which aims to
develop insights about plausible development paths for the Dutch electricity system.
However, due to the intrinsic dynamic complexity of the system, this puzzle goes
beyond intuition, and the static approaches have very limited to offer. Therefore, a
simulation-based analysis is utilized for looking into the dynamics of change in the
Dutch electricity supply system.

Following section introduces the simulation model developed for this analysis;
namely ElectTrans. Introduction focuses mainly on the scope of the model, and the
way electricity supply system is conceptualized. Section 3 is devoted to the
simulation experiments, which includes the main base case experiment, and four
scenario runs. The last section summarizes the experiment outcomes, and discusses
future directions.

2. Model Description

This section provides an overview of the model developed for exploring transition
trajectories for the Dutch electricity system, i.e. ElectTrans. The overview aims to
clarify the system boundary, the main assumptions, and the conceptual representation
of the system and the system actors that are represented in the model. The model is
developed based on the actor-option framework (Yiicel 2010) for modeling socio-
technical transitions.

ElectTrans is an agent-based model, which explicitly focuses on multiple actor groups
within the electricity system (e.g. generation companies, households, industrial users,
the state as a regulator, etc.). Besides being represented in an agent-based
architecture, the model builds upon the fundamental notions of the system dynamics
perspective: the feedback within and among these agents, the delays between the
actions and their consequences, and the delays in the perception of these
consequences are seen as the major factors that condition the system behavior.

The description of the model is structured around the major aspects of the system; i.e.
demand, supply, and regulation. A more detailed documentation of the model can be
found elsewhere (Yiicel 2010).

a. End-users and the electricity demand

A preliminary investigation points to different user categories, which differ in the
demand patterns as well as preference structures that drive their decisions. Clustering
these heterogeneous user groups in a single category is evaluated to be insufficient for
the purposes of this study. Therefore, four groups of end-users are represented in the

a0
model, which are industrial users, commercial users, horti-/agricultural users, and
households.

It is possible to name two major supply options for all actor groups, i.e. using
electricity supplied via central generation, and adoption of distributed generation
options! for self-generation. In the way it is conceptualized in the model, the primary
choice to be given by an end-user is about getting the electricity from central grid, or
generating electricity via distributed generation options. There are two grid-based
options in the model: gray electricity and green electricity’. Various distributed
generation options are also available, such as wind turbines and gas engine CHPs.
Table | provides aggregate list of the supply options, including both grid-based and
distributed ones, available in the model, as well as their appropriateness for individual
actor groups. Whether an option is appropriate for a particular actor group, or not is
determined mainly on the basis of demand-capacity match criteria. If commercially
available sizes of an option are close to average end-user demand for an actor group,
that option is defined as usable for that actor group.

Table 1. Electricity supply options for end-user groups in ElectTrans

2/@ |2 |/s
2 |2¢/)8¢
Option Name 3 23 g 3 4 3

Zl? (3 |7
Grid Electricity (Gray) uw Ira ea a
Grid Electricity (Green) w a w a
Micro-CHP 4] Mu
PV Roof 4) ir) a
CHP (Gas Engine) ca w
CHP (Gas Turbine) uM Mu ir}
CHP (CCGT) 4
Biomass Combustion uM uM
Biomass Gasification a uM
Wind Turbine (Inland) uw ca w a
Wind Farm (Inland) a w aw
Wind Farm (On Shore) a
Wind Farm (Near shore) M
Wind Farm (Off-shore) a
M: Option appropriate/usable for the actor type
&: Option not appropriate/usable for the actor type

The set of diverse options enables capturing alternative transition trajectories (e.g.
distributed cogeneration, green supply, etc.) into which the actors may push the
system via their choices. Moreover, this wide coverage enables studying the

' The terms ‘distributed generation’ is used similar to the sense it has been defined by Pepermans et.al.
(2005). Briefly, a distributed generator is defined to be one that is not dispatchable by the system
operator.

2 Electricity generated from renewable sources such as wind, solar, biomass, etc.

Aina
competition among available options, which lacks in most models with a single-
technology focus (e.g. diffusion of wind generation).

In the midst of this option variety, it is the decisions of the actor groups that will
influence the way system will shape in the long run. These decisions are not just
based on cost figures, but they are multi-dimensional decisions where environmental
and social issues also play a role. Representation of such a decision process in the
model is of primary importance. Although it is not possible to represent the
complicated decision process of individuals as it is, it is possible to formulate decision
heuristics that provide decisions that resemble the decisions of real actors. Referring
to the decision analysis field (Keeney and Raiffa 1993; Keeney and Gregory 2005), in
order to formulate such a decision process a preference structure, which specifies the
relevant importance of the assessment criteria, is used. In the preference structure
implemented, the actor groups consider four criteria; cost of supply, price volatility,
environmental performance, and in-group familiarity. Among these criteria,
environmental performance refers to direct CO2 emissions caused per kWh electricity
generated by the evaluated options, and familiarity refers to the diffusion of the option
within the actor group to which the actor belongs. The weights of these criteria for an
actor specify the individual preference structure of that actor, which is the main factor
that differentiates the decisions of different actors in the midst of identical option sets.
For example, an actor giving more importance to familiarity characterizes a less
innovative user, who prefers to comply with the historical choices of the group it
belongs to. On the other hand, another actor weighing familiarity less is more inclined
towards opting for innovative options; hence represents a more innovative profile.
This preference structure is coupled with a variant of the /ogit function (Gensch and
Recker 1979; Ben-Akiva and Lerman 1985) in determining the shift of end-user
demand among electricity supply options.

As mentioned earlier, the model is an agent-based one, and the end-user agents in the
model represent large groups of actors, rather than individual ones. Due to this actor
aggregation, model agents represent large groups of actors as discussed above.
Aggregation of discrete decisions of such a large group converges to a continuous
process. Therefore, a continuous demand allocation formulation is used in the model:
at the end of each year, free demand for each agent is calculated and allocated among
feasible options according to the function used. Free demand is equal to the sum of
two terms; the first of them is the total demand satisfied, during the previous year, via
distributed generation capacity being depreciated, or grid-based supply contract being
expired (i.e. replacement component). The second term is equal to the growth in the
demand of the agent (i.e. expansion component).

Conventional gray electricity is accepted as the base-option in the model; the
attributes of the gray electricity (e.g. cost of supply) constitute the reference levels to
be used in assessing other options. For grid-based options, demand allocated to the
option represents new supply contracts. For the other options, it indicates the need for
capacity investment in that option. The generation capacity to be installed by the end-
user is equal to the capacity that can supply the demand allocated to the option
considering the technical properties of the option (e.g. seasonal availability). This way
end-user groups manage their portfolio of supply sources, either by renewing grid-
based supply contracts, or installing distributed generation capacity.

5190
b. Supply options and the generation companies

The end-users discussed in the previous section constitute only one side of the socio-
technical system. The other side of the story is related to the supply options, be them
distributed generation technologies, or grid-based supply. The technical and
economical attributes of the supply options are dynamic, and partially dependent on
the endogenous dynamics of the system.

For the distributed generation options (i.e. all options except grid-based gray and
green electricity supply), developments in technological and economical attributes of
these options are introduced as exogenous processes into the model. In formulating
exogenous technological or economical development of an option, it is assumed that
development will continue with a decreasing rate, and eventually converge to a pre-
defined future value (i.e. negative exponential growth). The specific values of initial,
as well as future values for technical and economical attributes of options are given in
the technical supplement, which is available from the authors upon request. In
specifying these initial and final values, data introduced in (Lako and Seebregts 1998;
Junginger, Agterbosch et al. 2004; Voorspools 2004; Breeze 2005; Caputo, Palumbo
et al. 2005; Martinus, Blesi et al. 2005; Seebregts 2005; Freris and Infield 2008) are
taken as the basis.

For the grid-based supply options, attributes such as cost of supply, price volatility
and CO, emissions per kWh energy are directly determined by the available generator
park, as well as the dispatching regime. Furthermore, profitability of certain generator
types considered for capacity expansion, as well as operation hours of already existing
generators are dependent on the demand pattern exerted by the end-users. Therefore,
the provision system for the grid-based central supply options is included in the
system boundary, and explicitly represented in the model. The grid-based system is
introduced in two sections; the generation capacity, and the generation companies
managing this capacity.

=" Generation plants and import/export capacity

The set of central generation plants (i.e. generator park) constitutes the major
technological part of the grid-based supply system. The Dutch generator park consists
of around 60 active generators with generation capacities from 15 MWe to 695 MWe
(Seebregts 2005; Rédel 2008). The generators also show variation regarding the
generation technology utilized; hence the primary fuel used. As of 2006, 28% of the
active generation capacity is coal-based, whereas 69% is natural gas-based. Borssele
nuclear plant constitutes 3% in the Dutch central generation capacity. Besides these
already operational generators, a set of new generators is already in the permission or
construction phase. According to TenneT (TenneT 2007; TenneT 2007), an additional
10.000 MWe of capacity has been announced by generation companies to be
operational by 2014. Approximately 40% of this new capacity is natural gas-based,
whereas the remaining 60% is coal-based.

Each generator is represented by a discrete entity in the model. This representational
choice is mainly driven by two issues that may influence the model behavior. First of
all, generators are decommissioned in discrete chunks, rather than a gradual manner.
The impact of discrete changes may have a different impact on the investment
behavior of generation companies, compared to a gradual capacity decommissioning.
Secondly, load dispatching is dependent on the technical and economic properties of

6190
the available generators. Aggregation of these properties and representing a group of
generators as a single entity may yield different dispatching results. This difference
will eventually yield different load allocation patterns, which is very influential in
price and emission dynamics. Therefore, each generator in the model represents an
actual generation plant, and its economic and technical properties are defined
accordingly. A generator goes through three stages during its lifetime before being
decommissioned; announced, under-construction, and active. All generation plants
active as of 2006 are initialized using the technical and economic characterization
reported in Rédel’s dissertation (Rédel 2008). Additionally, expected capacity
expansions in TenneT reports (TenneT 2008) are also introduced into the model as
announced capacity.

= Generation companies

Generation companies are mainly responsible for short-term operation of the
generators they possess, as well as long-term management of their generator park.
The short-term operation mentioned above involves unit commitment decisions, and
price bidding in the electricity market, which are directly related to load dispatching
to take place in the market*. Regarding operational behavior, generation companies
are assumed to be acting non-strategically. This implies two assumptions related to
load dispatching. Firstly, it is assumed that they will not withhold generation capacity
for strategic reasons, as it is discussed to be plausible in oligopolistic markets (Green
2004). Secondly, it is assumed that there is no inter-actor cooperation in price bidding
to increase the prices in order to increase overall revenues, which is possible due to
low price elasticity of demand.

Another short-term decision of generation companies is related to biomass co-firing.
Most of the existing coal-fired generators can also use biomass-coal mixtures (up to
10-15% biomass) without significant loss of efficiency (Caputo, Palumbo et al. 2005;
van den Broek, Faaij et al. 2008). Providers check the additional cost of shifting to co-
firing against the additional benefits, make a fuel choice (coal alone, or biomass co-
firing) for coal-fired options.

The long-term decisions of the generation companies are related to capacity
management, i.e. investment and decommissioning. Generation companies
periodically make an assessment of individual units in their generator park. In this
assessment, decommissioning decisions are mainly based on expected lifetime of the
technology used in a generation unit. A unit at the end of it is lifetime is
decommissioned. Additionally, an old unit close to its lifetime may also be
decommissioned if the unit has been making loss. Generation companies’ expansion
decisions are mainly driven by profit expectations. Capacity expansion decisions are
dependent on four basic pieces of information; forecasts about fuel prices, forecasts
about demand, forecasts about active generation capacity connected to the grid, and
information about the feasible investment options.

The forecasts of the generation companies regarding the first three determinants of
investment decisions are based on companies’ perceived information about the
market. This involves fuel prices, seasonal load levels, average electricity prices, and

5 Load dispatching plays an important role in average cost of generation, total emission levels, and
profitability of generators. Therefore a more detailed description of its representation in the models is
given in the appendix.

7190
other revenue related quantities, such as market prices for carbon emission permits or
green certificates. The companies utilize an adaptive trend estimation and univariate
trend extrapolation heuristic to develop their future estimates regarding these key
variables. In adaptive trend estimation, new information perceived by the agent at the
end of each simulation step is used to update the historical average, and trend
information. When necessary, this average and trend information is used to develop a
forecast via simple extrapolation. It should be noted that, in implementing such a
heuristic it is not claimed that actual generation companies are using a forecasting
approach this simple. However, Sterman demonstrates that this heuristic imitates the
forecasts developed by electricity utilities with a significant success (Sterman 1988).
The adaptive trend estimation and extrapolation heuristic used in this model is
identical to the one analyzed by Sterman, which is documented in detail in his work.

The forecasts of the generation companies regarding market conditions are used to
evaluate available investment options. Expected cost and revenue figures are
calculated for each option, and combining these figures with investment and fixed
O&M costs, the company comes up with a return on investment (ROJ) estimate for
each option (Pirog, Stamos et al. 1987). The option with the highest ROI is selected
for investment. If the highest ROI is less than expected ROI of the agent, which is
15% in the base case, the agent does not make any investment for capacity expansion.

As in the case of unit commitment, it is assumed that generator companies are not
acting strategically in their investment decisions. Therefore, they only invest when
there is room for profit. Strategic behavior that are plausible in oligopolistic electricity
markets such as overinvestment for preventing new entrants, or inter-actor
underinvestment cooperation for increasing prices are not covered in the current
version of the model, but considered for future extensions.

While conducting the feasibility analysis briefly described in the previous paragraphs,
agents rely on information they have about technical and economical properties of
available options, such as electrical efficiency, availability, and variable O&M costs.
Actors are not assumed to possess perfect information about these attributes.
Therefore, actual investment options and information available to actors about these
options are differentiated in the model. In the implementation, actors learn about
improvements in the actual properties of options with a perception delay.

The generation unit options that are available for investment in the model are given in
Table 2. Each option has a pre-specified generation capacity, which is derived from
common commercial sizes (Breeze 2005; Rédel 2008). As in the case of end-user
options, generation options’ technical and economical properties develop over time in
the model. The rate of this development is proportional to the gap between the current
level of the attribute and the plausible future level. In other words, development rate
is defined to be proportional to room-for-development. Current and plausible future
values for technical (e.g. electrical efficiency, availability) and economic attributes
(e.g. investment cost, fixed O&M cost) of options are determined based on recent
studies on the issue (Lako and Seebregts 1998; Voorspools and D'haeseleer 2003;
Vogstad 2004; Voorspools 2004; Seebregts 2005; Davison 2007; Rédel 2008; van den
Broek, Faaij et al. 2008).

ena
Table 2. Grid-based investment options available in the model

S comps Capacity Option Name Capacity
Option’ Name: (MWe) (continued) (MWe)
PC‘ (Single unit) 400 CCGT? (Single unit) 400
PC (Double unit) 800 CCGT (Double unit) 800
pee unit) wath 800 CCGT SOFC’ 400
7 CCGT (Double unit)
IGcc 300 with Cos 800
IGCC with CCS 300 CCGT CHP 200
Gas Turbine 50 Nuclear 1000
Gas Turbine CHP” 50 Wind farm 20
Biomass/Waste Fired 10 Wind farm (Off-shore) 100

Although the set of options given in Table 2 is defined in the model, not all of them
are available for investment in the beginning of the time horizon of the study. All
options with CCS are assumed to be available for investment after 2025, considering
legal and technological progress required. In the base run of the model, it is also
assumed that the informal position of the Netherlands regarding nuclear energy (i.e.
no further nuclear installations) will stay intact.

c. Regulation of the market

The Netherlands committed to the goal of increasing the share of renewable
electricity generation, and the recent goal is declared as having 20% of the total
electricity from renewable sources by 2020. In order to achieve this target, several
policies have been used since early ‘90s. Despite having a meta-direction of greening
the electricity supply, the Dutch government’s preference has been towards generic
policies, which does not focus on specific technology or applications. Both supply-
side (e.g. investment support, or feed-in subsidies) and demand-side (e.g. taxing gray
electricity) policies have been utilized so far. However, demand-side policies are not
being used anymore, and the focus seems to be on boosting capacity investment via
supply-side policies operationalized via SDE'° program (SenterNovem 2009;
SenterNovem 2009; SenterNovem 2009; SenterNovem 2009). Implementations of
these policies showed significant variation within short intervals, which caused the
Dutch renewable energy policy not having the best consistency record compared to
other EU countries like Germany or Spain (van Sambeek and van Thuijl 2003;
Junginger, Agterbosch et al. 2004; Agnolucci 2007). Since it is almost impossible to
endogenously imitate such a policy implementation behavior in detail, a simpler
approach is employed: it is assumed that the Dutch government will continue
supporting capacity development in renewable electricity generation via increasing
the economic competitiveness of renewable generation options, which is the main
objective underlying various support policies recently employed. The state, as it is
represented in the model, compensates renewable generation capacity via paying a

* PV: Pulverized coal

5 CCGT: Combined cycle gas turbine

© CCS: Carbon capture and storage

7 SOFC: Solid oxide fuel cell

S IGCC: Internal gasification combined cycle

° CHP: Combined heat and power

‘Stimulating sustainable energy production (i.e. Stimulering Duurzame Energiproductie, in Dutch)

ana
subsidy per kWh electricity delivered to the grid, which is equal to the gap between
the average market price of electricity and the cost of generation via that specific
option. This is similar to the way the currently used SDE support program functions.

3. Simulation Experiments

The model introduced in the previous section, i.e. ElecTrans, is initialized in
correspondence with the state of the actual system in 2006. Prior to full-scale
experimentation, a thorough verification and validation process is conducted in order
to assess the appropriateness of the model. Verification process, simply, covers the
assessment of the model in terms of implementation problems (i.e. precision in
converting the conceptual model to the computer environment). In this case, it is
conducted via extensive code walk-through tests, as well as input-output tests for
isolated sections of the model. Validation involves the assessment of the model
structure as well as the model behaviour. The structure of ElecTrans is validated via
several tests, such as isolated behaviour plausibility, and extreme value tests.
However, an extensive behavioural validation was not possible due to the
inappropriateness of the historical data from the actual system for such a procedure.
Since the Dutch electricity system has been going through an important liberalization
process, the historical data before and after this process is generated by different
system structures. Since ElectTrans corresponds to the post-liberalization structure,
historical data from the pre-liberalization period is not a meaningful input for a
behaviour validation test. Therefore, only a limited behaviour validation procedure
could be conducted.

Considering the technological, social and economical aspects, ElectTrans provides an
environment for a wide range of experiments. Only a limited subset of such
experiments, which is selected on the basis of contextual relevance, is reported in this
paper. First of all, it is aimed to present the plausible directions of change for the
Dutch electricity system under commonly discussed developments, such as the rapid
improvement of clean coal technologies, or the policy interventions leading to more
expensive carbon emission permits. As will be apparent in the discussions, the
simulation results are not considered as future predictions for the Dutch electricity
system, but these results are used to develop a better understanding about the way the
Dutch electricity system may react to particular type of changes.

For each case to be discussed below, multiple simulation replications are performed.
This is mainly due to procedural processes related to the agent-based simulation that
are probabilistic in nature, such as shuffling the order of the agents before each
decision round. In order to filter out the impact of such probabilistic processes on the
conclusions to be drawn, 50 replications are performed for each case, and the mean
values of these replications are presented during the discussions, unless otherwise
indicated.

a. Base case
This case constitutes a basis for comparison for the analysis. The case assumes the
continuation of the recent trends with no major changes. In relation to technology, this
translates to a normal technological development pace, as well as a normal innovation
climate. All generation technologies available in the beginning of the analysis period
are assumed to develop according to the widely accepted trajectories. In other words,
their technical and economical properties, such as investment cost or electrical

inna
efficiency, converge to the most likely values discussed in the literature. Also no
significant shift in the commercial introduction of new options, such as carbon
capture and storage, is expected in the case. The context in which the end-users and
the generation companies act is mainly defined by the fuel prices and the regulations
in the model. Regarding the fuel prices, it is assumed that the coal and natural gas
prices will follow their historical growth averages. Initial fuel prices and
corresponding yearly increase percentages are given in Table 3.

Table 3. Fuel prices in the base case

Fuel Initial price nar year Gi)
Coal 1.8 Euro/GJ 15:
Natural Gas 4.2 Euro/GJ 2
Biomass 5 Euro/GJ 0
Uranium 4.5 Euro/MWhe 0

The regulator is assumed to continue supporting the renewable generation options
according to the currently dominant perspective of making them economically
competitive against the conventional technologies. Uncertainty is quite high regarding
the evolution of the carbon permit-related policies beyond 2012. Both the
commitments on total emissions as well as the national permit allocation schemes
may undergo significant changes, or may stay as it is currently. In the base case, no
significant change is assumed. In accordance with that, the emission permit prices are
assumed to continue to settle around the current insignificant levels (i.e. below 10
Euro/ton C02).

No significant change on the end-users’ side related to the norms and priorities is
expected in this experiment. Therefore, the preference structures, which are
represented by the weights of different objectives as discussed before, that guide the
actions of these actors stay the same throughout the simulation run.

The base version of the model is simulated for the 2010-2040 period. The dynamics
regarding the primary choice of the end-users indicate that an increasing share of the
aggregate end-user demand is directed towards the grid-based electricity supply
options (Figure 2). The first decade of the simulation, a steady increase in the share of
the distributed generation is observed. This increase, which can be misinterpreted as
an early transition phase, ceases after the first decade, and the share of the distributed
generation falls below its initial level of 30%. The factors that lead to this growth-
and-decline pattern in the share of the distributed generation, which can also be
characterized even as a backlash of a transition towards a decentralized structure, are
discussed in the following paragraphs. Figure 2 also shows that the grid-based supply
prevails as the dominant supply option, and, furthermore, most of the demand directed
towards the grid-based supply is for the traditional gray electricity. In order to
understand the factors leading to this outcome, a closer look at the system is required.

11190
Generation Percentage by Source

Central
so || Distrib uted

% Total Generation

o
zoos 201 ents aman aa25anao asso
Year

Figure 2. Allocation of end-user demand between central and distributed supply

The breakdown of the distributed generation according to the energy source is
presented in Figure 3, which shows the aggregate situation over all end-user groups.
Further breakdown of the distributed generation according to end-user groups can be
seen in Figure 4. A significant decline in the natural gas-based supply is observed in
the figure. One of the underlying causes of such a development is the increase in
natural gas prices. The flagship of distributed generation is gas-fired CHP facilities in
the Netherlands. However, this option loses its competitive advantage, even
considering the benefits from cogeneration, due to high gas prices and discontinuation
of former cogeneration support schemes. As a result, only very limited replacement
investments are observed against a continuing retirement of the existing CHP
capacity. Only for household users, an insignificant increase in natural gas-based
generation is observed, which is due to limited diffusion of micro-CHPs. This
constitutes one of the issues related to the decline in the share of the distributed
generation in the system.

xaot Total Distributed Generation by Source
3
25
2 Natural Gas
——wina
5 Biomass
6 =
1 Pe
——_—
os
é = ae ee eas
2005 2010—~—=«IS 020 anes SOROS «AO

Year

Figure 3. End-users’ electricity consumption by energy source (aggregated over all end-user
groups)

19190
Distributed @gieration by Source Cindustimistitarte Generation by Source (Agricultural Users

2 Q
2000 2a28 Zon 2000 2a20 znd
ear vear

Distributed Generation by Source (Commer iataiuemd Generation by Gouree (Household User
5000, Te00

| 7S
f

ooo
» 3000
2000
soo

4000

o. 9 Srceererrceremenl
000 2020 2o40 2000 2020 Boao

[ Natural ga ‘wana Biomass Sorat]

Figure 4. End-users’ electricity consumption by energy source

An important increase in the amount of electricity generated via green options,
especially via biomass and wind-based options, is observed during the first half of the
simulation. This growth compensates the aforementioned decline in natural gas-based
generation, and yields the growth in the share of the distributed generation. The pace
of increase stagnates in the second half of the simulation, and even a slight decline in
the wind-based generation is observed (see Figure 3). Going over the major relations
depicted in Figure 5, it is easier to understand the factors behind this stagnation. In the
growth phase, the SDE support scheme, which supports the green generation via
compensating the cost gap between the grid-based and the green electricity, is the
main factor behind the increase. However, SDE makes green options equally cost
competitive with grid-based options, but not more profitable than that. Hence, the
critical push factor is the extra benefit obtained from green certificates, which
fluctuates as a consequence of the balance between green electricity supply and
demand. However, the negative feedback loop L1 in the figure pulls the certificate
prices down. Observing the demand-supply dynamics for the green electricity
presented in Figure 6, it is clear that this extra benefit diminishes as a supply surplus
situation emerges over time.

Certificate Prices
SDE Support

Profitability of
green generation

Capacity Investments

Figure 5. Demand-supply interaction for the green generation capacity

12190
One way to neutralize the impact of this negative feedback loop is to support the
demand growth. However, in the absence of demand-side support policies (like REB
which was abolished in 2004), the green electricity loses its economical appeal for the
end-users, and its utilization is confined only to the environmentally friendly end-
users. In summary, in the absence of policies like REB, the demand growth stagnates,
leading to the dominance of L1 in pulling down the capacity investments.

Apart from this, there is a secondary factor that plays an important role in the growth
of wind-based generation: carrying capacity. The surface area where wind turbines
can be located, due to both wind availability and environmental concerns, is naturally
not infinite for inland projects. Due to significantly lower installation costs, inland
turbines are the most profitable wind-based generation option in the model. Hence, in
the early phase most of the investments are for inland wind turbines/farms. Increasing
costs, due to less favourable locations, for the inland wind turbines is the secondary
factor that slows down the growth in wind-based generation. Going back to Figure 5,
this means that there is a second negative feedback loop that counteracts the growth in
the wind turbine installations, i.e. L2.

Finally, PV rooftop panels emerge as an important distributed generation option,
especially, for household users. Since the model does not consider surface area issue
for PV panels, the extent of the solar-based generation should be evaluated with
caution. Despite this caveat regarding the limits of solar-based generation, it is seen
that it may establish a position in some market niches.

x10" Green Electricity

0
2o5 2018 ents aman 2a2s—enao—saS SCO
Year

Figure 6. Total green electricity consumption ys. generation

As already discussed in the beginning, end-users’ choices over time indicate a
growing load on the central grid, and in the absence of a significant increase in the
distributed supply this growth may be even more than expected. The development of
the load on central generation system, as well as the evolution of the installed capacity
is given in Figure 7. A striking observation is a significant over-capacity during the
early phases of the simulation. Rather than being a result of endogenous investment
behaviour of the model agents, this over-capacity is rooted in the behaviour of the real
generation companies. The bulk of generation capacity that is commissioned before
2015 is the set of generation plants already announced by the generation companies
and reported by TenneT (2007a). This covers an approximate total of 8500 MWe
generation capacity, for which TenneT has already entered into connection agreement
as of 2009, and excludes other announced plans without a connection agreement. As

1A10
seen from the figure, the load on the central grid is increasing very slightly, and
almost constant in some periods, during the 2010-2015 period. Despite the growth in
total electricity demand, only a small portion of this growth is felt on the grid, since
increase in the distributed generation compensates some of that demand increase.
However, following the decline in the share of distributed generation, the load on the
central grid enters the faster increase phase observed beyond 2020. In short, it is the
dynamics on the distributed power generation side that causes the change in the pace
of the load growth, rather then the actual growth in electricity demand.

The aforementioned issue shows a novel complication in the electricity supply
system; increasing demand flexibility. This poses a great uncertainty for the
generation companies. When the central grid is the only option for the end-users, the
key forecast to be made for the capacity investments is about the increase in the
demand of the end-users. However, with the increasing number of options for the end-
users, additional dimensions are required in the forecasts, such as the end-users’
investments in distributed generation capacity. Although this is not something we
directly observe in our simulations, the increasing uncertainty about the demand may
lead to risk-averse investment behaviour in the multi-actor liberalized market setup.
Eventually, this may cause problems such as insufficient generation capacity in the
long run.

Installed Capacity vs. Peak Load (Public Grid)

2 20 BI
&
10 |
16 seaiegeer 4
14 bat 4
raft
10
ons 201g ents an2n 2025 anao—~ass CO

Year

Figure 7. Installed capacity vs. load on the central grid

The over-capacity situation that is observed in the beginning of the simulation has a
set of consequences. Firstly, it causes a decline in the average price of the grid
electricity (see Figure 8). This is mainly due to upcoming coal-based generators
capturing the share of the gas-based generators in the market. A more indirect
consequence of the over-capacity situation is the investment barrier it yields. The
generators connected to the central grid are high value investments with long lifetimes
(e.g. 20-30 years). Due to the value, they constitute important commitments for the
generation companies: their likelihood of shifting to alternative generation
technologies is very low as long as these commitments exist. Additionally, they are
also very likely to demonstrate strong fight-back reflexes against any new entrants
through price competition. This means that there is no major possibility of altering the
generation park until 2020 since new investments are not promising in such a system
state. In other words, any policy intervention during this period will only have impact
on the short-run operational decisions, but not that much on the way the generator

15190
park evolves. The model agents’ tendency towards not making any capacity
investment until the 2020s is a reflection of this problem in the simulation runs.

a Averege Electricity Price (Public Grid)

2 - 4

ao} po

Euro Atvie
ae |
_—
~
4

\ i

2
gos ai ents aman 2a2sana0—aaas CO
Year

Figure 8. Average electricity price (public grid)

The investments in the central generation system are dominated by the coal-based
options even beyond the initial over-capacity period. Among others, the IGCC plants
emerge as a favourable generation option. The consequence of this investment
tendencies over time lead to the shift of dominance from natural gas to coal in the
Dutch central generation system. Towards the final periods of the simulation run,
natural gas-based generators only supply electricity for peak and a portion of the
medium load, whereas base load is almost totally supplied by coal-based generators.
Since there is no significant emission penalty in the base case, CCS is not adopted at
all, causing increased emission levels

This is partially understandable considering the marginal fuel cost advantage over the
natural gas-based generators, and the lack of significant carbon emission penalties.
However, the coal-based generators typically serve base load. In more practical terms,
it makes sense to invest in a coal-based generator only if the generator is expected to
be generating electricity with a high utilization level (e.g. 70%). This puts a constraint
on the expansion of the coal-based generators. However, as it is seen in Figure 9, this
constraint does not seem to be very strong for the Dutch system.

Generation Percentage by Fuel Type

Coal
a0 || —-— Naturalcas
——wina

Uranium 4
Biomass
Solar

Sa

% Total Generation

sof et i pncrnaes pomeeargua Ey
ee

ii ———
2on5 nin ents an2n—2u2s— nan
Year

Figure 9. Share of primary fuels in total central generation

14190
Triggered by this observation from the simulation results, we further investigate the
issue, and the character of the Dutch load duration curve (LDC) (more specifically the
slope of this curve) is identified to be the main factor in creating such a coal-friendly
environment. Figure 10 demonstrates two simplified LDCs with different slopes. The
areas underneath the curves are equal; i.e. the total energy demand is the same, but the
pattern of the demand is different. In these two cases, we consider the situation of a
base-load generator that needs to be active at least 67% of the time in a year. The
shaded areas represent the part of the total demand that can be served with this
particular generator. Clearly, this part gets much larger when the LDC gets less steep.
The Dutch LDC, not being steep one, provides a large room for the coal-based
generation, and this explains the extent to which the share of coal-based generation
can increase in the simulations.

Steep LDC case Plain LDC case

Figure 10. Example about the role of the slope of LDC on the share of the base load

Figure 11 presents the carbon emission related consequences of the generation
portfolio evolution. The emissions increase only slightly during the pre-2020 period.
Beyond this point, combined impact of two factors result in a significant growth pace
in emissions: first of all the demand on the central grid increases faster; secondly the
share of coal-based, i.e. ‘dirty’, generation in the central generation increases during
the same period. Hence, significant emission levels are reached in the absence of
emission prevention measures, limited diffusion of green generation and no interest
towards CCS applications in the base scenario.

yy 210" Carbon Dioxide Emission

= Emissions from central generation
—-— Emissions from distributed generation
——Tetal emissions

ton coz

i—
0
2os 2018 ents aman 2a2s nao

Year

Figure 11. Carbon dioxide emission due to electricity generation

b. Strong regulatory pressure for change
The results obtained from the base case show that intrinsic processes of the energy
system is not likely to lead to a transition when left alone. Such a result should not be

17190
surprising. Additionally, the carbon emission levels experienced in the base case seem
to be unacceptable within the contemporary European context. Therefore, the second
scenario includes a strong regulatory pressure for ‘de-carbonizing’ the system, and
investigates the plausible developments within the system triggered by such a
pressure.

Currently, the national emission commitments beyond 2012 are not clear, and the
ambitions of EU and the member states beyond that time point carries significant
uncertainty. In this scenario, it is assumed that the Dutch government, as well as other
EU states, pushes harder for emission reduction. This can be conceptualized as
allocation of fewer permits, which should eventually lead to increasing permit prices.
In initializing the model for this experiment it is assumed that the permit price
increases until 2020 reaching 60 €/ton carbon dioxide emitted, and then stays at that
level until the end of the time horizon. Although there is no common expectation
about the future levels of the permit price, a price above 40 €/ton is evaluated to be a
significant penalty.

Different from the base scenario, the share of the distributed generation shows a
growth in the final decade of the run in this scenario (Figure 13). This late increase is
primarily related to the increasing gray electricity prices: the grid-based supply option
loses its cost advantage against the distributed generation (especially against the
wind-based generation) due to this price increase. However, this does not explain why
there is no change in the early periods despite the significant increase in the prices
from the very beginning of the run. An intuitive expectation would be a much earlier
increase in the share of the green generation as the carbon permit price increases. The
explanation can be found in the way the current sustainable energy support program
(i.e. SDE) works: SDE does not provide a fixed feed-in tariff for renewable
generation, but it provides a dynamic support to compensate the gap between the
price of the grid electricity, and the cost of renewable generation. Therefore, as long
as the grid-based electricity’s price stays below the cost of generation via wind, the
wind-based generation will not gain an extra competitive advantage as a result of the
increases in the grid electricity prices. In other words, SDE acts like a buffer, and
makes the system insensitive to price changes as long as grid-based electricity is
cheaper than the distributed generation.

In this scenario experiment, we also observe interesting consequences of the way
different policies interact within the current setup of the Dutch system. SDE is a
policy scheme that aims to increase the electricity generation via renewable options.
The carbon penalties are used in order to steer the system away from carbon-intensive
generation methods. At the first glance, these two policies are both against the fossil
dependency, and may be expected to have a stronger impact on the system when used
simultaneously. However, the simulation experiments do not support such
observations. The permit costs are reflected in the cost of generation, and this
increases the marginal generation cost of the grid generators. This results in the
permit costs being transferred to the end-users; i.e. higher electricity prices. In the
same time, due to higher grid electricity prices, the subsidies to be paid by the state to
renewable electricity generators decreases: the gap between the marginal generation
costs of grid-based and distributed options get narrower. This can be seen in the
illustration given in Figure 12. As an overall consequence, the tighter carbon permit
allocation policy used by the state shifts the burden to end-users. The renewable

19/90
generation options are supported to the same level as in the case of the base scenario,
total subsidy to be paid by the state is less, and end-users are facing more expensive
grid electricity. This can be evaluated as an unintended joint consequence of two
separate, but interrelated policy interventions.

SDE Subsidy
‘SDE Subsidy
Permit Costs
Generation
cost per kh
by renewable
‘option X
Grid eecticiy
price par kvin
Grid electricity
price perxwn | Avg. Marginal Cost ‘Avg. Marginal Cost
of the Grid of the Grid
Electricity Electricity
Base Case Higher permit costs

Figure 12. Composition of electricity prices with the SDE subsidy

Generation Percentage by Source

Central
so || Distrib uted

% Total Generation

o
zoos 201 ents aman aa25anao asso
Year

Figure 13. Allocation of end-user demand between central and distributed supply

Some significant differences are observed with respect to the dynamics of distributed
generation (Figure 14). First of all, the decline in natural gas-based generation ceases
towards the end, and even a slight increase is observed. This can be explained by
increasing cost competitiveness of small-scale generators despite the increase in
natural gas prices, since they are excerpt from carbon payments! "Secondly, wind and
biomass-based distributed generation follow different trajectories in this scenario.
Until 2025 generation costs of the both options are higher compared to the grid-based
generation. Therefore they are both supported via SDE. Since SDE provides a subsidy
to compensate the difference from the grid-based generation (i.e. options get different
levels of subsidy, and their generation costs are made equal with this support), there is
no difference between the wind and biomass options. Beyond 2025, average cost of

"' Generators with an output capacity below 20 GWh are excluded from the carbon permit market

10190
grid-based electricity exceeds the cost of wind-based generation. However, biomass-
based generation is still more expensive. This marks the point where wind obtains a
financial advantage over both grid-based supply and other distributed generation
options. This causes the decoupling of the dynamics related to the biomass and wind-
based generation: one experiencing a steep increase, while the other barely sustaining
its share in distributed generation.

x1ot Total Distributed Generation by Source

Natural Gas

—— wine
Biomass

Solar

ae oe uf 4
as 5
2 ae el at
15 - Sos Boa |
A a al
1 gh |
os sige orca a |
0
2005 2nin ais ann anasanag 2035 2040

Year

Figure 14, End-users’ electricity consumption by option

When the situation for the central supply system is examined, a totally different
picture from the base experiment is seen (Figure 15). Three periods can be identified
for the central supply system. The first one is the pre-2015 period, which resembles
the same period from the base case. A decrease in the share of natural gas, and a
corresponding increase in the share of coal are observed in this period. Beyond 2015,
the impact of the high permit price becomes visible. The natural gas-fired generators
having much less emission levels (i.e. almost 50% less per kWh electricity generated)
become economically competitive against the coal-fired generators, and re-gain their
share in total generation. This happens through the increase in the share in load
dispatching in the short run, and through the increase in the investments to gas-based
options in the longer run.

Another development is the increase in biomass-based generation. This takes place in
the form of co-firing in central coal-fired plants. Once permit prices exceed a
threshold beyond which emission reduction due to biomass co-firing compensates the
extra cost of biomass, generators start shifting to biomass co-firing. The situation
between 2015 and 2025 seems like coal is about to disappear from the Dutch system.
However, a strong comeback is seen beyond 2025. One important factor in this come
back is the increase in the natural gas prices, which causes the emission advantage to
erode against the coal-based generation. The second factor is the commercial
availability of CCS, which eliminates the emission disadvantage of the coal-fired
plants. Such a rapid change in the economic competitiveness of options leads the
sharp shift in the shares of coal and gas in central generation.

aaa
Generation Percentage by Fuel Type

Coal
a0 || —-— Naturalcas
wind
ao Uranium 4
Biomass
70 || —— solar epaecerge 4

% Total Generation

& ee
2o05 2019 ants an2nzaz5——sana0~—~=asS SCO
Year

Figure 15. Share of primary fuels in total central generation

The observed changes that related to the comeback of the cola are very rapid for a
capital-intensive system like the electricity supply. There are a couple of issues that
set the scene for such rapid changes. First of all, both investment and load dispatching
processes are driven predominantly by purely economical concerns. In other words,
there is one property of the options that dominate the decisions of the actors; i.e. the
generation cost. However, the nature of this property is reversible: any development
in this property may be reversed in a very narrow time window. This is exactly what
happens in this case. Increasing natural gas prices, and the introduction of CCS yield
a very rapid change in the relative costs of the coal-based and gas-based options. The
dominance of a single reversible property in the actor decisions is the primary factor
behind this comeback.

Secondly, the liberal market structure with multiple actors also enables such a
dynamic behaviour. Since the agents in the model are maximizing their individual
profits, they see no problem in making investments that will make other agents”
investments redundant. This yields to an overcapacity situation where some of the
gas-based investments become unprofitable, and practically passive much before
completing their lifetimes.

As a result, we observe that if the (desirable) changes in the system are dependent on
reversible developments, precautionary measures for ‘anchoring’ these developments
may prove useful. For example a progressive carbon permit price that follows the
increase in natural gas prices would help to sustain the cost advantage of the gas-
based generation. In other words, it would help to anchor the gained advantage.
Secondly, rapid changes in the relative situation of the competing options are
observed to have the potential to lead to overcapacity situations in multi-actor settings
such as the electricity markets.

c. Optimistic technological development scenario
One of the uncertainties about the future of the electricity supply is related to the
extent of the technological developments. Some optimistic scenarios claim significant
room for development for the green technologies in economic (e.g. investment and
operating costs) and operational performance (e.g. efficiency, capacity availability).
On the other side, new innovations and technological developments are also expected
related to the fossil fuel-based conventional technologies. This scenario explores the
impact of such optimistic technological progress: the development limits of the

a1100
properties of different options are raised, and the widespread introduction of the new
technologies (e.g. CSS, SOFC, IGCC) takes place earlier. The modified parameter
values corresponding to these changes can be found in Appendix C.

Despite the aforementioned changes, the major behaviour patterns are observed to be
very similar to the base case. This behavioural insensitivity is mainly due to the SDE
policy, as discussed already in the previous scenario experiment. The economical
properties of the distributed generation options are more favourable in this case, but
this development is not likely to make them cheaper than the grid-based supply. As
long as this is the case, the changes in the economical properties of the options only
change to subsidies to be paid by the state (i.e. generation costs are lower, and the gap
to be compensated by the subsidy is less), but fail to provide the extra push to initiate
a system-wide transition.

x10" Green Electricity

Domestic generation os ete
Domestic consumption 4

une

0
2os 2018 ents amen 2025 anao «aaa Co
Year

Figure 16. Demand ys. supply of green electricity

The share of the grid-based generation, as well as the composition of the capacity
connected to the central grid is almost identical to the base case. Slight changes are
observed regarding the composition of the distributed generation: first of all there is
some increase in the domestic green electricity generation, despite the absence of an
increase in the demand for green electricity. This is mainly triggered by the slight
increase in the economic viability of the biomass-based options. When the situation of
the end-users is studies, it is observed that PV panels and m-CHPs obtain a higher
share in the supply portfolio for the household-type end-users. However, the impact
of this is a negligible development when the aggregate situation over all end-user
groups is considered.

7100
x1ot Total Distributed Generation by Source

— Natural Gas

"= — Wind
aslo. Le i | —— Biomass
= —— soiar

Al
gis
é

af

os

fi ioe

foos—~2010 201s 20202025 e037 —~—~aaSS OHO

Year

Figure 17. End-users’ electricity consumption by option

This scenario experiment reveals the behavioural insensitivity of the Dutch electricity
supply system to technological uncertainty under the current SDE support scheme.
Naturally the insensitivity mentioned here is within the time horizon of the runs. The
delays in the development of the generation options, and their active utilization
(adoption, investment, etc.) create a sort of systemic inertia. In the presence of such
inertia, it is difficult to observe significant changes in the system even under
optimistic condition.

Before proceeding, it should be noted that the exploring the technological uncertainty
demands much more than just considering optimistic development trajectories for
some options, as we do in this experiment. This experiment is conducted just to
explore if any of the currently available novel options will stand out in case it
develops beyond the common expectations.

d. ‘Greening end-users’ scenario
The final scenario to be discussed in this chapter is related to the plausible changes in
the electricity supply system due to significant changes in the preferences of the end-
users. Since the end-users, and more specifically their behavioural identities, are
explicitly represented in the ElectTrans model as a vital aspect of the socio-technical
system, the model allows us to conduct such experiments.

As already mentioned, the different end-user groups are characterized according to
the scale of their electricity demand, and their preferences that guide these users in
their supply choices. In this scenario, the priority of the environmental issues
experience significant increases for all actor groups. In a way, the environmental
concerns gain some priority for all actors in comparison to the purely economical
concerns. In line with this, a steady ‘greening’ takes place among the household-type
users during the simulation run: the environmental friendliness (i.e. carbon emission
in this context) becomes the primary criteria for supply choices by the end of the time
horizon. A similar development takes place for the agricultural and commercial end-
users. They go through a slower preference shift, and environmental friendliness
becomes equally important with economical ones. Industrial users also experience
some level of ‘greening’, but the economical aspects still dominate their choices
through out the time horizon of the analysis.

92100
The changes in the end-users’ preferences trigger a demand formation for the green
electricity. Being the readily accessible and most cost-competitive one, the grid-based
green electricity attracts most of this newly forming demand. As seen in Figure 18 the
demand for green electricity makes a steeper climb compared to the base scenario. As
a consequence of higher levels of green electricity demand, the supply surplus
diminishes towards the end of the time horizon, which increases the green certificate
prices. This latter increase provides an incentive for further investment and green
capacity, hence the green generation, continues to grow throughout the time horizon,
rather than stagnating, as it was the case in the base scenario. This observation also
supports our previous conclusions in the base case regarding the interplay of the
demand and supply of green electricity.

The early supply surplus and the intrinsic investment delays create some level of
inertia within the system. As a result, the impacts of the preference changes that start
around 2015 on the green generation dynamics are only felt beyond 2025.

rao* Green Electricity

Domestic generation
-— Domestic consumption

6

fa
zoos 2018 anis e020 anesanan 2035 onan
Year

Figure 18. Demand ys. supply of green electricity

The aforementioned increase in the green certificate prices provides an extra push for
green distributed generation options. This keeps the share of the distributed
generation at higher levels compared to the base scenario. Although it is not possible
to talk about a notable increase, the share of distributed generation sustains the %40-
level (Figure 19).

Generation Percentage by Source

—— central
so || Distrib uted
* a a
ees eee

% Total Generation

0
ans 201 ents aman 2a2s—ana0~=CaS SCO
Year

Figure 19. Allocation of end-user demand between central and distributed supply

aA1I00
As seen in Figure 20, the biomass-based generation experiences a steady increase,
while the wind-based generation stagnates following an early rapid growth. Being an
initially more attractive option, wind-based generation demonstrates an earlier
growth. However, once the favourable inland spots are used, the cost of capacity
expansion gets less attractive for the wind farm installations. This can be considered
as a consequence of the capacity crowding dynamics, where the favourable spots for
the inland wind farms constitute a natural capacity limit beyond which the options
starts losing its economical attractiveness. As a result, as the limits of land-based wind
installations are approached, biomass captures the economic advantage and attracts
most of the demand for green electricity generation. This indicates that being an
option that has the potential to experience an early take-off, the wind-based
generation may be unable to sustain this growth unless the technological
developments close the gap between the already favourable inland and other wind
farm installations in economical terms.

The shift of demand to green distributed supply options results in a slightly less load
on the central generation plants compared to the base scenario. This slight decrease
does not have a major impact, and the dynamics regarding the central generation are
pretty similar to the base case. When the overall system is investigated, the
dependency of the system on conventional fossil fuels is intact (Figure 21). The
shares of energy sources, except biomass, have very similar dynamics with the ones
observed in the base case. As briefly discussed above, the extra demand for green
options triggered by the general greening trend among end-users yield an increased
share for biomass-based electricity generation in the Dutch context. This indicates a
very strong internal inertia in the system that is hard to overcome just by changes in
the end-user preferences. At least, a change at the scale that is considered in this
experiment only has a marginal impact on the system.

x1nt Total Distributed Generation by Source

Natura Gas
—— wine
A Biomass

£45 Solar
6
ak
as A
a = ee i acl
zoos 2018 amis 2020 ~—=«anes~=n =~

Year

Figure 20. End-users’ electricity consumption by option

96100
Generation Percentage by Fuel Type

Coal
a0 || —-— Naturalcas
wind
ao Uranium 4
Biomass
70 || —— solar 4

% Total Generation

a

&
2ons nin ants an2n——anzs nan
Year

Figure 21. Share of primary fuels in total central generation

4. Conclusions

The Dutch electricity supply system is going through an era that can be characterized
with changing institutional, economical, technological and social conditions. Despite
the intrinsic inertia against change, which is typical to large-scale socio-technical
systems, these changing conditions create a backdrop of change for this system. This
study aims to explore the extent of change that may be expected, and plausible
development directions under recent conditions.

The electricity system is an interconnected constellation of actors, technologies and
infrastructures. The feedbacks among these components, and delays embedded in
their interactions cause such a system to possess high-level of dynamic complexity.
Therefore, a dynamic simulation model is utilized to analyze the system behavior
under differing conditions. A simulation model that incorporates both the demand and
supply sides of the system is developed, and calibrated to represent the Dutch
electricity system. The model builds upon fundamental system dynamics notions, and
utilizes an agent-based architecture to formalize the conceptualization of the system.

The reference scenario experiment indicates that central generation sustains, and even
extends its share in the supply of electricity. This indicates the deterioration of the
current important position of distributed generation in the Dutch context. As a direct
consequence of the opening gap between coal and natural gas, future capacity
expansions are likely to be dominated by coal-based generators. Lack of significant
carbon penalties, and the relatively flat load duration curve of the Dutch electricity
demand enable such a development. The second scenario addresses one of these
points by introducing progressive carbon permit prices. Such a high penalty on carbon
emissions suppresses coal-based investments, the development of the grid-based
generation capacity changes significantly. However, it is seen that unless the progress
in the penalty keeps up with the price gap between coal and gas, a strong comeback of
coal-based generation is possible. This scenario also demonstrates that greening and
de-carbonizing policy measures are closely related, and rapid increases in the carbon
prices may result in the transfer of greening program costs directly to the end-users.
The third scenario depicts an optimistic technological development situation. This
scenario experiment reveals the behavioral insensitivity of the Dutch electricity
supply system to technological uncertainty under the current SDE support scheme:
even with optimistic development trajectories, the impact of this development on the

76100
system is observed to be insignificant within the considered 30-year time horizon. The
last scenario reported in this paper addresses the issue of ‘greening’ end-users. A
significant preference change in favor of environmental issues results in an important
increase in the demand for green electricity. This demand-push yields an increased
green capacity build-up compared to the reference case. However, the extent of this
increase is still limited considering the total electricity supply.

The system boundary used for this analysis is quite broad, and incorporates many
social and technical uncertainties. Due to space constraints only a small set of
experiments, which are considered to be relevant within the current policy debates are
discussed in this paper. In the course of on-going analyses, the model is being used
for extensive exploration, as the wide system boundary demands. This uncertainty
exploration goes beyond simple single-parameter sensitivity analysis, and includes
even sensitivity analysis based on different behavioral routines of the actors; a feature
that is possible in the agent-based architecture used. Analyses of the results obtained
from this exploration stands as the follow-up of the work reported in this paper.

Considering the implementation, some discrete processes in the electricity supply
system, and the potential importance of actor heterogeneity made an agent-based
architecture more suitable for this analysis. Despite benefiting from an architecture
that is non-native to the system dynamics field, the system representation extensively
relies on system dynamics concepts. In that respect, this study can be considered as a
typical example of mutualism between the established conceptualization and analysis
tradition of the system dynamics, and flexibility of object-oriented implementation.

References

Agnolucci, P. (2007). "Renewable electricity policies in The Netherlands."
Renewable Energy 32: 868-883.

Ben-Akiva, M. E. and S. R. Lerman (1985). Discrete choice analysis : theory and
application to travel demand. Cambridge, Mass., MIT Press.

Breeze, P. (2005). Power Generation Technologies. Oxford, Newnes.

Caputo, A. C., M. Palumbo, et al. (2005). "Economics of biomass energy utilization
in combustion and gasification plants: effects of logistic variables." Biomass
and Bioenergy 28: 35-51.

CBS (2009). CBS.

Davison, J. (2007). "Performance and costs of power plants with capture and storage
of CO2." Energy 32: 1163-1176.

de Vries, L. J. (2004). Securing the public interest in electricity generation markets:
The myths of the invisible hand and the copper plate. Delft, Delft University
of Technology. PhD.

Faber, A., M. Valente, et al. (2008). Domestic micro-cogeneration in the Netherlands:
An agent-based demand model for technology diffusion. DIME Working
Papers.

Freris, L. and D. Infield (2008). Renewable Energy in Power Systems. Chichester,
Wiley.

Gensch, D. H. and W. W. Recker (1979). "The multinomial, multiattribute logit
choice model." Journal of Marketing Research 16: 124-132.

Green, R. (2004). Did English generators play Cournot? Capacity withholdinh in the
Electricity Pool. Cambridge Working Papers in Economics, University of
Cambridge.

a7100
Junginger, M., S. Agterbosch, et al. (2004). "Renewable electricity in the
Netherlands." Energy Policy 32: 1053-1073.

Keeney, R. and R. Gregory (2005). "Selecting attributes to measure the achievement
of objectives." Operations Research 53(1): 1-11.

Keeney, R. and H. Raiffa (1993). Decisions with multiple objectives: preferences and
values tradeoffs. Cambridge, Cambridge University Press.

Lako, P. (2004). Coal-fired power technologies: Coal-fired power options on the
brink of climate policies. Petten, ECN.

Lako, P. and A. Seebregts (1998). Characterisation of power generation options for
the 21st century: Report on behalf of Macro task El. Petten, ECN.

Martinus, G. H., M. Blesi, et al. (2005). Technical and economic characterization of
selected energy technologies. Petten, ECN.

Pehnt, M., M. Cames, et al. (2006). Micro Cogeneration: Towards Decentralzed
Energy Systems. Netherlands, Springer.

Pepermans, G., J. Driesen, et al. (2005). "Distributed generation: definition, benefits
and issues." Energy Policy 33: 787-798.

Pirog, R. L., S. Stamos, et al. (1987). Energy economics : theory and_policy.
Englewood Cliffs, N.J., Prentice-Hall.

Rédel, J. G. (2008). Ecology, Economy and Security of Supply of the Dutch
Electricity Supply System: A Scenario Based Future Analysis Delft, Delft
University of Technology. PhD.

Seebregts, A. (2005). Appendix B: Description of the POWERS model (in Dutch).
Kerncentrale Borssele na 2013. Gevolgen van beéindiging of voortzetting van
de bedrijfsvoering. A. J. Seebregts, M. J. J. Scheepers, R. Jansma and J. F. A.
v. Hienen. Petten, ECN.

SenterNovem. (2009). "Duurzame warmte." Retrieved 28/09/2009, 2009, from
http://www.senternovem.n|/duurzamewarmte/subsidie-informatie/micro-
kk.asp.

SenterNovem. (2009). "EIA: Investeren in energiebesparing en duurzame energie."
Retrieved 28/09/2009, 2009, from http://www.senternovem.nl/eia/.

SenterNovem. (2009). "MEP: Milieukwaliteit van de Elektriciteitsproductie."
Retrieved 29/09/2009, from http://www.senternovem.nl/mep/.

SenterNovem. (2009). "SDE (Stimulering Duurzame Energieproductie)." Retrieved
28/09/2009, 2009, from http://www.senternovem.nl/sde/.

Smekens, K. E. L. (2005). Technology R&D and CO2 policy scenarios: The
MARKAL model work for SAPIENTIA. Petten, ECN.

Sterman, J. (1988). "Modeling the formation of expectations: The history of energy
demand forecasts." International Journal of Forecasting 4: 243-259.

TenneT (2007). TenneT Quality and Capacity Plan 2008-2014 - Part I. Arnhem,
TenneT.

TenneT (2007). TenneT Quality and Capacity Plan 2008-2014 - Part II. Arnhem,
TenneT.

TenneT (2008). Security of Supply Monitoring Report 2007-2023. Arnhem, TenneT.

van Damme, E. (2005). Liberalizing the Dutch electricity market: 1998-2004. Tilburg,
CentER - Tilburg University.

van den Broek, M., A. Faaij, et al. (2008). "Planning for an electricity sector with
carbon capture and storage: Case of the Netherlands." International Journal of
Greenhouse Gas Control 2: 105-129.

van Sambeek, E. J. W. and E. van Thuijl (2003). The Dutch renewable electricity
market in 2003. Petten, ECN.

re100
Vogstad, K.-O. (2004). A system dynamics analysis of the Nordic electricity market:
The transition from fossil fuelled toward a renewable supply within a
liberalised electricity market. Department_of Electrical Power Engineering.
Trondheim, Norwegian University of Science and Technology. PhD.

Voorspools, K. (2004). The modelling of large electricity-generation systems with
applications in emission-reduction scenarios and electricity trade. Leuven,
Leuven KU. PhD.

Voorspools, K. and W. D'haeseleer (2003). "The impact of the implementation of
cogeneration in a given energetic context." IEEE Transactions on Energy
Conversion 18(1): 135-141.

Yiicel, G. (2010). Analyzing Transition Dynamics: The Actor-Option Framework for
Modelling Socio-Technical Systems. Delft, Delft University of Technology.
PhD.

r000

Metadata

Resource Type:
Document
Description:
Recent developments constitute a backdrop of change for the Dutch electricity
Rights:
Date Uploaded:
January 1, 2020

Using these materials

Access:
The archives are open to the public and anyone is welcome to visit and view the collections.
Collection restrictions:
Access to this collection is unrestricted unless otherwide denoted.
Collection terms of access:
https://creativecommons.org/licenses/by/4.0/

Access options

Ask an Archivist

Ask a question or schedule an individualized meeting to discuss archival materials and potential research needs.

Schedule a Visit

Archival materials can be viewed in-person in our reading room. We recommend making an appointment to ensure materials are available when you arrive.